Company
Ziehl
Description
TR440
Bill of material
TR440
ORDERNO
TR440
CONTACT_SERVICE_LIFE__ELECTRICAL
contact service life, electrical
30 x 106 operating cycles
CONTACT_SERVICE_LIFE__MECHANICAL
contact service life, mechanical
gGgL 10 A
CONTROL_VOLTAGE_US
control voltage us
ACDC 24 – 240 V, 05060 Hz, 2 W 4 VA
CONVENTIONAL_THERMAL_CURRENT_ITH
conventional thermal current ith
max. AC 400 V
DIMENSIONS__W_X_H_X_D_
dimensions (w x h x d)
RS 485 – sensors
EMC_COMPATIBILITY
emc compatibility
-40 °C ... +65 °C EN 60068-2-2 dry heat
EMC_ELECTRICAL_INTERFERENCE
emc electrical interference
EN 61000-6-2
FINELY_STRANDED_WITH_WIRE_END_SLEEVE
finely stranded with wire end sleeve
per 1 x 2.5 mm2
GALVANIC_INSULATION
galvanic insulation
2…25 Hz ±1.6 mm 25 ... 150 Hz5 g
HOUSING_INTERNAL_PROTECTION
housing internal protection
per 1 x 2.5 mm2
INRUSH_CURRENT__AT_10___ED_
inrush current (at 10 % ed)
max. 10 A
LIMITS
limits
DC 20.4 - 297 V AC 20 - 264 V
LINE_CONNECTION_SINGLE_STRAND
line connection single strand
96 x 96 x 80 mm
MEASUREMENT_CYCLEMEASUREMENT_TIME
measurement cyclemeasurement time
2.5 s
MEASURING_RANGE
measuring range
-199°C. 850°C -199°F .. 999°F
MOUNTING
mounting
IP 20
NO_GALVANIC_INSULATION__ONLY_DEVICES_WITH_RS_485_INTERFACE_
no galvanic insulation (only devices with rs 485 interface)
Us – relays, sensors, (RS 485) ..... DC 3820 V relays – sensors, (RS 485) ..... DC 3820 V
NOMINAL_OPERATING_CURRENT_FOR_REVERSING_SWITCH
nominal operating current for reversing switch
3 A AC15 250 V; 2 A DC13 24 V
NOMINAL_OPERATING_CURRENT_IE__AC_15_
nominal operating current ie (ac 15)
30 A max. 4 s
OPERATING_TIME
operating time
250 V
PERMISSIBLE_AMBIENT_TEMPERATURE
permissible ambient temperature
100 %
POLLUTION_LEVEL
pollution level
4000 V
RATED_IMPULSE_WITHSTAND_VOLTAGE
rated impulse withstand voltage
1 x 106 operating cycles at AC 250 V 6 A 2 x 105 operating cycles at AC 250 V 10A cos ϕ 0,6
RATED_INSULATION_VOLTAGE_UI
rated insulation voltage ui
3
RECOMMENDED_SERIES_FUSE
recommended series fuse
6 A AC 250 V
REDUCTION_FACTOR_AT_COS_Φ_0_3
reduction factor at cos ϕ 0,3
0,5
RELAY_DATA_K2__K3_AND_K4
relay data k2, k3 and k4
3 x 1 change-over contact
SENSOR_CONNECTION
sensor connection
Pt 100 according to EN 60751 (23-wire version)
SENSOR_CURRENT
sensor current
≤ 0.7 mA
SENSOR_RESISTANCE___LINE_RES_
sensor resistance + line res.
max. 500 Ohm
SWITCHING_CAPACITY
switching capacity
max. 2000 VA (Ohmic load) max. 120 W at DC 24 V
SWITCHING_CURRENT
switching current
max. 6 A
SWITCHING_VOLTAGE
switching voltage
1 reversing switch
TEMPERATURE_DRIFT
temperature drift
0.04°CK
TERMINAL_STRIP_PROTECTION_TYPE
terminal strip protection type
Front panel IP 54 (with seal), rear IP 20
TOLERANCE
tolerance
± 1°C, ± 1 Digit
VIBRATION_RESISTANCE_EN_60068_2_6
vibration resistance en 60068-2-6
EN 61000-6-3
WEIGHT
weight
Panel mounting, Cut-out 91+0.7 x 91+0.7 mm
NAME
name
TR440