Crawled Part

このカタログは、自動的に収集されました。選択されたパーツは、STEPフォーマットのみの対応です。これ以外のフォーマットでのダウンロードを希望される場合は弊社から各メーカーに代診いたしますのでお知らせください。

私の情報がサプライヤーに送信されることに同意します
Catalog navigation
CADモデル選択
選択可能な製品数: 1
HELP_VARIABLE
Company
Ziehl
Description
STR100
Bill of material
STR100
ORDERNO
STR100
ACCURACY
accuracy
±2 % of scale
ALARM
alarm
1 nc contact, operating current principle
CONTAMINATION_LEVEL
contamination level
4000 V
DEGREE_OF_PROTECTION__IP_CODE_
degree of protection (ip-code)
any
DESIGN
design
Housing ....... PA 6.6 Socket ....... PA 6.6 GF25
DIMENSIONS__H_X_W_X_D_
dimensions (h x w x d)
1 x 2.5 mm2
ELECTRICAL_CONTACT_LIFE
electrical contact life
1 x 105 operations with 230 V6 A
EMC___INTERFERENCE_RESISTANCE
emc - interference resistance
class B, EN 61326
EMC___INTERFERENCE_TRANSMISSION
emc - interference transmission
100 %
FACTOR_OF_REDUCTION_AT_COS__Φ___0_3
factor of reduction at cos. ϕ = 0.3
0.5
FITTING_POSITION
fitting position
35mm standard rail EN 60715 or with M4 screws
FLAME_CLASS
flame class
82 x 42 x 121 mm
HYSTERESIS
hysteresis
10 °C (±25 %)
INTERNAL_FUSE
internal fuse
T 0.16 A time-lag (or slow blow 0.25 A)
LINE_COMPENSATION
line compensation
0.5 Ώ normally
LINE_CONNECTION_SOLID_WIRE
line connection solid wire
1 x 1.5 mm2
MATERIAL
material
UL 94 V-2 UL 94 HB
MAX__AMBIENT_TEMPERATURE
max. ambient temperature
built-in type, pluggable
MECHANICAL_CONTACT_LIFE
mechanical contact life
3 x 107 operations
MOUNTING
mounting
1 mm at 25 Hz 10 g at 25 …100 Hz
ON_PERIOD
on period
0...50 °C EN 600068-2-2 Dry Heat
OVERVOLTAGE_CATEGORY
overvoltage category
EN 61000-6-2, EN 61326
POWER_CONSUMPTION
power consumption
2 W
RATED_IMPULSE_VOLTAGE
rated impulse voltage
III
RATED_INSULATION_VOLTAGE_UI
rated insulation voltage ui
2 (normal)
RATED_OPERATIONAL_CURRENT_IE
rated operational current ie
2 A AC15 400V 2 A DC13 24 V 3 A AC15 230V
RATED_SUPPLY_VOLTAGE_US
rated supply voltage us
AC 230 V DC 24 V
RECOMMENDED_FUSE
recommended fuse
4 A quick acting
RESET
reset
internal reset button or contact (no) Y1, Y2
RESET_PUSH_BUTTON_Y1__Y2
reset push-button y1, y2
1 V 1 mA DC
SENSOR_CONNECTION
sensor connection
2-wire Pt 100 RTD according EN 60751IEC 751 α = 0.00385
SHOCK_RESISTANCE
shock resistance
app. 300 g
STRANDED_WIRE_WITH_FERRULES
stranded wire with ferrules
Housing ....... IP 40 Socket....... IP 20
SWITCHING_CHARACTERISTIC_MINIMUM
switching characteristic minimum
AC 250 V
SWITCHING_CURRENT
switching current
max. 6 A
SWITCHING_POWER__RESISTIVE_LOAD_
switching power (resistive load)
max. 2000 VA max.48 W at DC 24 V
SWITCHING_VOLTAGE
switching voltage
max. AC 400 V max. DC 300 V
TEMPERATURE_FACTOR
temperature factor
0.2 K10 °C
TEMPERATURE_LIMIT
temperature limit
adjustable, see temperature range
TERMINAL_CURRENT_MAX_
terminal current max.
3.15 mA
TERMINAL_VOLTAGE_MAX_
terminal voltage max.
15 V open terminals 2 V with Pt 100 and highest temperature
TOLERANCE_VOLTAGE
tolerance voltage
50 60 Hz
VIBRATION_RESISTANCE
vibration resistance
10 g for 20 ms, 20 g for 4 ms
WE_RECOMMEND_AN_RS_SUPPRESSOR_TO_AVOID_HIGH_VOLTAGE_SPIKES_WHEN_A_CONTACTOR_IS_CONNECTED_
we recommend an rs-suppressor to avoid high voltage spikes when a contactor is connected.
1 no, potential-free
NAME
name
STR100
Preview - Generation
プレビュー
フォーマット
ファイル
3D
2D

Embedded user actions