Crawled Part

이 카탈로그는 자동으로 크롤링됩니다. 선택한 부품은 STEP포맷에서만 사용할 수 있습니다. 만일 사용 가능한 모든 형식을 원하시면 제조업체에 연락해 드리겠습니다.

내 데이터가 카탈로그 잠재 고객에게 전송 될 수 있음에 동의합니다.
카탈로그 탐색
CAD모델 선택
사용 가능한 제품: 1
HELP_VARIABLE
Company
Ziehl
Description
SPI1021
Bill of material
SPI1021
ORDERNO
SPI1021
ADJUSTMENT_RANGE
adjustment range
50 ms
ADJUSTMENT_RANGE_PHASE___N
adjustment range phase – n
Real root mean square measurement both half waves
ADJUSTMENT_RANGE_PHASE___PHASE
adjustment range phase – phase
AC 10…310 V ( 5 V 0 is displayed)
CONSTRUCTION_FORM
construction form
55 mm
CONTACT_SERVICE_LIFE__ELECTR_
contact service life, electr.
AC 15…530 V ( 5 V 0 is displayed)
CONTACT_SERVICE_LIFE__MECH_
contact service life, mech.
1 x 106 operating cycles at AC 250 V 6 A 2 x 105 operating cycles at AC 250 V 10 A cos φ 0.6
CONTACTOR_RESPONSE_TIME__SECTION_SWITCH_
contactor response time (section switch)
Pr1,2 all Pr3 L1 only
CONTROL_VOLTAGE_US
control voltage us
ACDC 24-270 V, 040...70 Hz, 1,8W 6,5 VA DC 20,4...297 V, AC 20,4...297 V
CONVENTIONAL_THERMAL_CURRENT_ITH
conventional thermal current ith
25 A max. 4 s 50 A max. 1 s
CURRENT
current
Adjustable 0.5...99.0 s
CURRENT_INX
current inx
DC 15…35 V
DELAY_AT_US_ON
delay at us on
DC 15…35 V
DIMENSIONS__W_X_H_X_D_
dimensions (w x h x d)
each 1 x 4mm2
DISPLAY_ACCURACY
display accuracy
3-phase withwithout N
DISPLAY_RESULT
display result
max 175s
DURATION
duration
4000 V
EMC___NOISE_EMISSION
emc - noise emission
V6
EMC___NOISE_IMMUNITY
emc - noise immunity
EN 61000-6-3
FINELY_STRANDED_WITH_WIRE_END_FERRULE
finely stranded with wire end ferrule
IP 30
FREQUENCY_RANGE
frequency range
45,00...65,00 Hz
FRONT_TO_BACK_SIZE
front-to-back size
90 x 105 x 69 mm
HYSTERESIS
hysteresis
± 0.04Hz ± 1 digit
INRUSH_CURRENT__AT_10___ED_
inrush current (at 10 % ed)
6 A AC 250 V
INSULATION_GROUP
insulation group
100 %
MEASUREMENT_ACCURACY
measurement accuracy
Adjustable 0.05 (±15ms)…130.0 s
MEASUREMENT_ERROR__WITH_N_
measurement error (with n)
± 0.8 % of the measurement value
MEASUREMENT_ERROR__WITHOUT_N_
measurement error (without n)
100V -1 digit (res. 1 V) 100V -1 digit (res. 0.1V)
MEASUREMENT_FUNCTION
measurement function
Adjustable 0.05 (±15ms)…130.0 s
MEASUREMENT_PRINCIPLE
measurement principle
Adjustable 1.0…99.9 V
MEASUREMENT_RANGE
measurement range
2,0...20,0°
MEASUREMENT_VOLTAGE_PHASE___N
measurement voltage phase – n
AC 015…300 V
MEASUREMENT_VOLTAGE_PHASE___PHASE
measurement voltage phase – phase
AC 015…520 V
NOMINAL_OPERATING_CURRENT_IE__AC_15_
nominal operating current ie (ac 15)
gGgL 6 A
OPERATING_TIME
operating time
-20 °C... +55 °C (EN 60 068-2-1 dry heat)
OUTPUT_VOLTAGE__U
output voltage +u
3 mA
PERMISSIBLE_AMBIENT_TEMPERATURE
permissible ambient temperature
EN 61000-6-2
PERMISSIBLE_TOLERANCE
permissible tolerance
„Pass“ = passed, „Fail“ = failed
PHASES
phases
150V 2,5Vs, ≥150V 5,0Vs
POLLUTION_LEVEL
pollution level
300 V
PROTECTION_CLASS__HOUSING
protection class, housing
IP 20 Mounting snap-on fastening on 35 mm mounting rail acc EN 60 715 or with M4 screwed attachment (additional bar not included in the scope of delivery)
PROTECTION_CLASS__TERMINALS
protection class, terminals
approx. 250 g
RATED_IMPULSE_WITHSTAND_VOLTAGE
rated impulse withstand voltage
III
RATED_INSULATION_VOLTAGE_UI
rated insulation voltage ui
II
RATED_CONNECTION
rated-connection
SPI1021 must be supplied with a UPS (5s)
RECOMMENDED_SERIES_FUSE
recommended series fuse
30 x 106 switching cycles
RESET_TIME
reset time
Adjustable 2…20 s
RESPONSE_TIME
response time
Adjustable 3…240 s
SLOPE_RATE_FREQUENCY
slope rate frequency
measured value – trigger value ≤±5% Response time80…120ms
SLOPE_RATE_VOLTAGE
slope rate voltage
0,05Hzs
SURGE_CATEGORY
surge category
2
SWITCHING_VOLTAGE
switching voltage
6 A
VOLTAGE_DROP
voltage drop
Max. AC 440 V
VOLTAGE_Y0___Y12
voltage y0 – y12
3 mA
WIRING_CONNECTION_SINGLE_STRAND
wiring connection single strand
each 1 x 2.5mm2
NAME
name
SPI1021
미리보기 - 생성
프리뷰
포맷
파일
3D
2D

내장 된 사용자 작업