사용 가능한 제품: 1
HELP_VARIABLE
Company
Ziehl
Description
RCM1000V
Bill of material
RCM1000V
ORDERNO
RCM1000V
ACCURACY_5060_HZ
accuracy 5060 hz
± 2%, ± 3 digit
ACCURACY_60_HZ
accuracy 60 hz
± 10%, ± 3 digit
BURST
burst
EN 61000-4-4 ± 4 kV pulse 550 ns, f = 5 kHz, t = 15 ms, T = 300 ms
CABLE_FOR_EXTERNAL_TRANSFORMER
cable for external transformer
≤ 10 m, single wire, ≥ 0,75 mm2
CONTAMINATION_LEVEL
contamination level
2
DELAY_ALARM_OFF
delay alarm off
adjustable 0 ... 999 s
DELAY_ALARM_ON
delay alarm on
adjustable 0,03 ... 10,0 s (Prog. 2 = 0,03 ... 500,0 s)
DESIGN
design
V4, 4 TE, mounting height 55 mm
DIMENSION__W_X_H_X_D_
dimension (w x h x d)
70 x 90 x 58 mm
ELECTROSTATIC_DISCHARGE
electrostatic discharge
IEC 61000-4-2 ± 3,8 kV discharge contact, ± 6 kV discharge air
EMITTED_INTERFERENCE
emitted interference
EN 61000-6-3
EXTERNAL_TRANSFORMER
external transformer
Type STWA3D... (20, 35, 70, 125)
FUNCTION_AT_LOSS_OF_SUPPLY_VOLTAGE_US
function at loss of supply voltage us
depending of configuration of relays closed current - relays release = alarm operating current - relays remain released (= no alarm)
HYSTERESIS_ALARM_1_ALARM_2
hysteresis alarm 1 alarm 2
10%...25%
HYSTERESIS_ALARM_1ALARM_2
hysteresis alarm 1alarm 2
10 % ... 25 %
INSTALLATION
installation
Snap mount on standard rail 35 mm acc. to EN 60715 or screws M4
MEASURING_RANGE
measuring range
0,003 A ... 9,999 A
MONITORING_RANGE_ALARM_1_ALARM_2
monitoring range alarm 1 alarm 2
0,010 A ... 9,999 A
OVERVOLTAGE_CATEGORY
overvoltage category
III
PROTECTION_HOUSINGTERMINALS
protection housingterminals
IP3020
RATED_AMBIENT_TEMPERATURE_RANGE
rated ambient temperature range
-20...+65 °C
RATED_FREQUENCY_RANGE
rated frequency range
50 ...500 Hz
RATED_IMPULSE_WITHSTAND_VOLTAGE
rated impulse withstand voltage
4000 V
RATED_INSULATION_VOLTAGE__UI_
rated insulation voltage (ui)
AC 300 V
RATED_RESIDUAL_OPERATIONAL_CURRENT__ION_
rated residual operational current (ion)
Alarm 2 - adjustable 0,010 A ... 9,999 A Alarm 1 - adjustable 50% ... 100% of alarm 2
RATED_SUPPLY_VOLTAGE_US
rated supply voltage us
AC DC 24V - 240V, 1,5W, 5 VA
RELAYS_K1__K2__ALARM_1__2_
relays k1, k2 (alarm 1, 2)
2 x 1 co-contacts, type 2, see general technical informations
RESPONSE_CHARACTERISTIC
response characteristic
Typ A
STARTUP_DELAY_POWER_ON
startup delay power on
adjustable 0 ... 10 s
STORAGE_TEMPERATURE
storage temperature
-20...+70 °C
SURGE
surge
IEC 61000-4-5 ± 2 kV
SWITCHING_LIMITS_FOR_ALARM_1ALARM_2
switching limits for alarm 1alarm 2
0 ... -20%
TOLERANCE
tolerance
DC 20,4 - 297 V, AC 20-264 V 50 ...500 Hz
WEIGHT
weight
app. 170 g
NAME
name
RCM1000V
미리보기 - 생성
프리뷰
포맷
파일
3D
2D

내장 된 사용자 작업